(a)
(b)
1.21 Z48 3J5 5~ΌΓ Time (min)
MW = 286
6.28 7.54
(M + H)+
2 N N H C H Î
M. > α -ν γ,Ν M W = 2 9 g
""—' • 1 • • · " ' ' i " — • " i -t i "
(M + H ) +
t " • • - •
to TO
03
J? Φ or.
(M + H)+
4 CHiV·: (M + H)+
MW = 284
•f τ τ r
(M + H)+
100 125 150 175 200 225 250 275 300
m/z
Figure 3. LC/APIMS separation and detection of a synthetic mixture containing 25 ng each of five benzodiazepines using a heated pneumatic nebulizer, (a) Full-scan LC/MS background subtracted total ion current (TIC) chromatogram and (b) posit ive ion APCI mass spectra. The total isocrat ic f low of 1.2 mL /m in CH 3 CN/CH 3 OH/H 2 0 (40:25:35, v /v ) , 10 m M ammonium formate buffer f rom a 4.6 m m X 250 m m Zorbax-Rx co lumn was passed through the LC/MS interface whi le the mass spectrometer was scanned f rom m/z 100 to m/z 350 at a scan rate of 3 s/scan wi th corona discharge ionizat ion. The APCI mass spectra in (b) were taken f rom the corresponding chromatographic peaks in (a). Peak ident i f icat ion: 1, oxazepam; 2, chlordiazepoxide; 3, nordiazepam; 4 , alprazolam; and 5, d iazepam.
shows the TIC chromatogram, UV chromatogram, and two plotted full-scan mass spectra for the packed-column SFC separation and APIMS detection of the components in a synthetic mixture of five corticosteroids. Approximately 25 ng of each component were injected to obtain the TIC
chromatogram shown in Figure 4a. For additional structural details, SFC/MS/ MS experiments were performed to provide the full-scan product ion mass spectra for each of these compounds, which yield abundant ions indicating the structure of these compounds (not shown here). This interface is also
Hamamatsu Hollow Cathode Lamps are now available from major lab suppliers. Hamamatsu single and multielement Hollow Cathode Lamps offer superior stability, spectral purity and output intensity, even for such elements as arsenic and selenium. They are compatible with most commercial spectrophotometers, including Beckman, Zeiss and Perkin-Elmer. And best of all, they're available from your local lab supplier.
For Application Information, Call 1-800-524-0504 1-201-231-0960 in New Jersey