CellBOX-R Programowalny sterownik zaworów regulacyjnych CellBOX-R is a programmable electronic pressure controller and logger, designed to work with pressure reducing valves (PRV) in water installations. CellBOX-R provides the ability to change the operating point of the main valve in daily rest cycle, for working days and holidays separately. In conjunction with the reducing valve's pilot system, CellBOX-R enables to achieve better stability of pressure, while adjusting its value to preset schedules. CellBOX-R is designed to provide higher reliability and greater flexibility of use than any conventional solution. Up to 96 thresholds of pressure level per day Logging of flow, input and output pressure Remote adjustment and data access Does not require mains power supply Compact and modular design SCADA systems compatibility

Transcript of Cell box r-eng

Page 1: Cell box r-eng

CellBOX-RProgramowalny sterownik zaworów regulacyjnych

CellBOX-R is a programmable electronic pressure controller and logger, designed to work with pressure reducing valves (PRV) in water installations. CellBOX-R provides the ability to change the operating point of the main valve in daily rest cycle, for working days and holidays separately. In conjunction with the reducing valve's pilot system, CellBOX-R enables to achieve better stability of pressure, while adjusting its value to preset schedules.

CellBOX-R is designed to provide higher reliability and greater flexibility of use than any conventional solution.

Up to 96 thresholds of pressure level

per day

Logging of flow, input and output

pressure

Remote adjustment and data access

Does not require mains power supply

Compact and modular design SCADA

systems compatibility

Page 2: Cell box r-eng

PRV reduces and stabilizes the outflow pressure at the desired level, regardless of inflow pressure and water demand. Application of the CellBOX-R device in the pressure reduction system can significantly reduce the operating costs of the water supply network by intelligently adjusting the pressure to the real needs of the area supplied.The device is equipped with pressure and flow logger. Measurement of input and output pressure is obtained by pressure transducers installed at the main valve. Measurement results and alarm state signalization could be transmitted by GSM/GPRS to the SCADA system.Dedicated battery enables activity of CellBOX-R for up to 5 years*. CellBOX-R is fully compatible with the SCADA systems.

We offer preconfigured SIM cards in the APN cellbox.pl and provide management service as well.We offer access to the measurement data via the Internet (any standard WWW browser).We ensure safety at every stage of transmission: IPSec tunnels with 3DES encryption for connections with customers servers and SSL protocol for WWW access.

Sample SCADA visualizations at https://telemetria.net.pl Login: demoOl pass: demoOl (login and password from "demoOl" up to "demo09")

Water distribution systems are exposed to bursts and leakages the more frequently, the higher pressure is on transmission pipelines and the more rapidly are pressure changes. Therefore the simplest way to reduce the leakage and frequency of the bursts is to control and stabilize the pressure in the water networks and to reduce the pressure to a strict minimum. This is done with pressure reducing valves.

Page 3: Cell box r-eng

Interfaces 4 configurable (4-20mA or 0-10V)

analog inputs 1 configurable (Pt100, Pt1000)

temperature analog input 2 counter inputs 7 digital inputs 3 digital outputs RS485

Logger Functio Cyclic logging Simultaneous logging of all

measured parameters GSM/GPRS data transmission Internal memory with storage for -

650000 samples Configurable logging interval from

5 seconds up Logging up to 352 alarm events Separate schedules for logging,

transmission and analog measurements

Real time data logging

Communication PC communication via external

interface SCADA communication via

industrial standard Fast and reliable GPRS/SMS

communication Remote service Remote software update Remote configuration Low cost data transfer Possible 2-way online

communication Alarm handling

Features Easy wiring terminals Large LCD

display (optional) Compatibility with every kind of actuator Built in GSM/GPRS module

5 operation modes (based on time schedule, based on flow conditions, manual, critical point mode - periodic or dynamic correction, constant or variable set point)

General Storage temperature: -40...+80°C Operating temperature: -

25...+55°C IP68 enclosure

Power source Dedicated rechargeable battery

pack Internal battery maintaining device work Optional external mains power supply