IBL Vacuum Box in UX15 Short summary Andrzej Zmuda andrzej.zmuda@cern.ch.

Post on 14-Jan-2016

219 views 0 download

Transcript of IBL Vacuum Box in UX15 Short summary Andrzej Zmuda andrzej.zmuda@cern.ch.

IBL Vacuum Box in UX15Short summary

Andrzej Zmudaandrzej.zmuda@cern.ch

Planned place to install

Planned method of installation

4 holes in angle bars 4 drilled blocks box on 4 scrubs

Electrical schematics prepared

Cable schedule updated

PT709, PT712 Vacuum pressures

UX15 level 6 FCTIR-000099

1 X3.1

NG4 2149068

1

connectUSA15 level 6 FCTIR-

000096Vacuum A USA15 Level 6

2 X3.2 2

3 X3.3 3

4 X3.4 4

PT809, PT812 Vacuum pressures

UX15 level 6 FCTIR-000099

1 X3.5

NG4 2149071

1

connectUSA15 level 6 FCTIR-

000096Vacuum B USA15 Level 6

2 X3.6 2

3 X3.7 3

4 X3.8 4

TS71x vacuum feedbacks plus spares

UX15 level 6 FCTIR-000099

1 X3.9

NG8 2149074

1

connectUSA15 level 6 FCTIR-

000096Vacuum A USA15 Level 6

2 X3.10 2

3 X3.11 3

4 X3.12 4

5 X3.13 5

6 X3.14 6

7 X3.15 7

8 X3.16 8

TS81x vacuum feedbacks plus spares

UX15 level 6 FCTIR-000099

1 X3.17

NG8 2149075

1

connectUSA15 level 6 FCTIR-

000096Vacuum B USA15 Level 6

2 X3.18 2

3 X3.19 3

4 X3.20 4

5 X3.21 5

6 X3.22 6

7 X3.23 7

8 X3.24 8

Box manufacturing in progress

Component installation progress

What is already done: Box installation location selected and agreed with CRYO Preliminary support design - done Electrical schematics for cable patching - completed IBL general cable schedule updated Box internal design completedWhat still needs to be done: Install all components inside the box – now (George) Add interconnection box 3D model in Smart Team

(Tomek B.) Install box in the cavern (George) Update electrical schematics for the Vacuum system

Summary

Thank you for your attention