SDP 3G SR Teluk Ewa
Transcript of SDP 3G SR Teluk Ewa
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 1/40
3G SITE DESIGN PACKAGE
LANGKAWI
NORTHERN
NWXXXX
TELUK EWA
KEDAH
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 2/40
SITE ID : NWXXXX
SITE NAME :
SITE CONFIGURATION : 1+1+1
FREQ. BAND : 3G
CELCOM (M) BHD
NORTHERN REGION
SITE DESIGN PACKAGE
Prepared by ;
TELUK EWA
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 3/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
Site Information
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 4/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
RF Design
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 5/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
Existing 2G Information
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 6/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
New 3G Information
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 7/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
Site Picture
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 8/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
Installation Plan
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 9/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
NORTHERN REGION
Mobile Checklist / BOQ
CELCOM (M) BHD
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 10/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
CELCOM (M) BHD
NORTHERN REGION
CME BOQ
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 11/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
NORTHERN REGION
Transmission Checklist
CELCOM (M) BHD
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 12/40
SITE ID : NWXXXX
SITE NAME : TELUK EWA
SITE CONFIGURATION : 1+1+1
Site Management Unit
CELCOM (M) BHD
NORTHERN REGION
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 13/40
CELCOM (M) BHD 1 Site Information
NORTHERN REGION
KEDAH 2 RF Design
3 Existing 2G Information
4 New 3G Information
5 Site Picture
6 Mobile Checklist / BOQ
7 Installation Plan
NWXXXX 8 Transmission Check List
TELUK EWA 9 CME BOQ
1+1+1 10 Site Management Unit
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 14/40
Site Approval
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
Prepared by
Name Mohd Nizam Mohd Noor (019-3160900)Company I-Convergence Sdn Bhd
Verified by
Name
Approved by
NameDepartment
Approved by
NameDepartment
Approved by
NameDepartment
SDP APPROVAL
Mobile Access Planning, Group Network Date
Date
Date
CME, Group Network Date
Transmission, Group Network Date
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 15/40
Site Informations
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
1.0
1.1 Site Location and Access
GPS Positi on
Latitude: 06 - 25 - 2.8
Longitude : 99 - 45 - 29.7
Altitude : 74m
1.2 Address : Vacant Land
Kampung Teluk Ewa
Pulau Langkawi
Kedah Darul Aman.
SITE INFORMATIONS
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 16/40
Site Informations
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
1.3 Site Details (Existing)
Type of Site : Land Cabin
Height of Building : N/A
Equipment Location : Cabin
Cabin Dimension : 7340 X 3680
Air Conditioning : 2 unit
Cable Ladder : YesLightning Protection : Yes
Type of Structure : 3 Legged Tubular
Boom Height : 3
Type of terrain : Hill
Access road : Earth / gravel / tar
Distance to main road : 1.5 km
Crane needed : No
Site Access Information : From Kuah Jetty, go towards Padang Lalang. After junction to
Padang Lalang, follow signboard to "Malayan Cement". Turn right
to quarters area and then turn left to tower area.
1.4 Contact Information
Celcom : Mizazuddin Bin Muhiyuddin
Telephone No. : 04-3973030 ext 1009
Fax No. : 04-3974040
Mobile No. : 019-5713060
Contractor Name : Mohd Nizam Mohd Noor
Telephone No. :Fax No. :Mobile No. : 019-3160900
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 17/40
a
b
c
d
a
a
b √
c
a
b
c
d
e
f
Tripod 6mtr
GI Pipe 2 mtr
Aesthetic Pole
Maximum Load (A)
Maximum Module
CPS Source
Rectifier -48V Data
Equipment Power Source
AC Power Supply Data
Land Cabin
Land Outdoor
Rooftop Cabin
Tower
TNB
3 Phase AC
SBC
Genset
Single Phase AC
Rectifier +24V
Swichtec Model
√ Rectifier -48V
Free DC Breaker (32A)
6
9
14.2
3
√ NoYes
Merlin Gerin
NoYesFree DB Space For Additional Breaker
Free DC Breaker (60A)Free DC Breaker (32A)
Current Module
Free DC Breaker (60A)
Current Load (A)
Free DB Space for Additional Breaker
DC Breaker Type
Specify
Site ID
Site NameNWXXXX
TELUK EWA
√ H-Boom
X-Pol Bracket Antenna Mounting
Antenna Type Model & PartCode
Feeder Clamp
√
√
7/8”
2 in 1
Feeder Type
Type Of BTS
2308
Horizon OD Horizon Micro
3
E1 Type
E1 Owner
2206 2102
2302
E1 Status
Celcom
Available
Alcatel√4
2G Vendor
√
Yes √
√ Yes
Plinth
Structure
Fiber Optic
TX INFORMATION
Structure Height 45
Lease Line
Room Reno
No
No
√ YesMGB Space Available
Horizon ID
√
Utilise Free
Motorola
MBO3
2202
MOBILE INFORMATION
√ MicroWave
2106
MBI5
TM Maxis Digi
MBO1
Ericsson
a
Shelter Type
V-PoleX-Pole Kathrein 730370
NoFeeder Through Available
meters
7340X3680 Cabin Size
Room Reno Size
Plinth Size
MBI3
M4M
1 5/8”
3 in 1
GI Pipe Boom
Special Bracket
Maxis
TM
2
√
CME INFORMATION
Power Supply
Space Available
Type Of Structure
√
Room Reno Rooftop
Roof top Outdoor
Guyed Mast
GI Pipe 6mtr
Monopole
Mini Structure
1
Type Of Site
√
GENERAL INFORMATION
√
Site Owner
Celcom
Digi
Cabin
Shelter
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 18/40
1
a
a
b
c
d
e
a
2
3
a
b
c Type
d
e
REMARKS:
1 Proposed new inlet and MGB outside cabin
2 To use 3 in 1 feeder clamp inside cabin to maximize space.
3 To rearrange existing 2G feeders inside cabin to free space for 3G feeders.
New (mtr)
New (mtr)
New (qty)
Additional Feeder Through (Qty)
Extend Existing(m)
Upgrade CPS System
Upgrade AC System
Cabin
Plinth New
Antenna Mounting New
Change Existing
Extend
Structure
TX ADDITONAL REQUIREMENTS
Refer to Tx BQ
MOBILE INSTALLATION METHODOLOGY
Swap 2G Eqpt. Rearrange EqptEquipment
Night
Specific Day
Equipment Mobilization
Lorry Crane
45 tonne
Day
Cable Gantry
No
Crane Requirements
Crane Access
Specific Times
20 tonne
Special crane
Open Roofing
Manpower
Special Tools/ Requirements
Qty
Specify
Antenna 2G
New Upgrade DB
Change to X-Pole
Add Module (Qty) Change Breaker (A) 20amp to32amp
Permit Requirements Yes
Change To Triband
Relocate Existing
MGB
Power Supply
CME ADDITONAL REQUIREMENTS
Genset
ADDITIONAL REQUIREMENTS FOR 3G IMPLEMENTATION
Change to Dual Band UMTS/1800Change to 1800 wideband
Shelter
TNB
b
Cable Ladder (Outdoor)
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 19/40
Site Requirements
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
2.0
2.1 Exiting Equipment
Existing Equipment Type
No Of Cabinet
Configuration
Comments : 2 cells only
2.2 Exi sting A ntenna Data 2GMake
Height AGL (m)
Gain (dBi)
Antenna Band
Polarization
Comments : Existing Vpol antennas
2.3 Feeder Data 2G
Total no. of feeders (pcs)
Type of feeders
Feeder lengths (m) Tx
Rx
TOTAL
Comments : To rearrange feeders to free space for 3G fedeers inside cabin
2.4 Antenna Support Detail
Type of antenna support : H-BoomNo. of H-Boom : 3
No. of G.I. Pipe : 6 (only four boom in use)
Length of G.I. Pipes (m) : 3
Comments : V-Pol antennas
EXISTING 2G
900
N/ACell 3
45
Kathrein 730370Cell 1
Kathrein 730370Cell 2
N/A
248
124
16
45
Cell 3 TOTAL
N/A 6
900
124 124 N/A
62 62 N/A
62 62
N/A
N/A 124
7/8 "7/8 "
16
N/A
+-45 N/A+-45
N/A
2
Cell 1 Cell 2
2
Alcatel MBI5
1
2+2+0
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 20/40
Site Name:
Site ID :
Existing 2G Site Name:
Existing 2G Site ID:
Co-locate Operator: Cluster No:
Version:
Lat (N-WGS 84- Decimal):
Long (E-WGS 84-Decimal):
BTS room Type: BTS Type:
BTS Configuration:
Transmission Type on site:
Cell Site RF Config uration
Cell ID
An tenn a Heigh t (mid. o f ant )
An tenn a Direc tion (d eg)Electrical Tilt
Mech. Tilt
Cable Length (m)
Cable Type (inch)
Technical Site Survey Report (Existing Antenna System Locations)TELUK EWA Survey Date: 14/06/2007
Sector 3
06 - 25 - 2.8
99 - 45 - 29.7 74
Sector 1
Others:
Sector 1 :
Phase:
Ams l(m):
Sector 2
Main road towards Datai, Kampung EwaSector 2 :
Sector 3 :N/A
La Farge Cement factory, Petronas oil tank area, main road towards Padang Lalang and jetty.Comment/ Problem:
Structure type 3 legged tubular
3 3
H-Boom
Height (m)Mount
Type H-Boom
No of Pole/ Tripod 2 2
62
3 legged tubular
0 0
7/8" 7/8"
0 0
62
45 45
40° 200°
Ant enna TypeModel Number 730370 730370
Beam width (deg) 65 65
2+2+0
Cabin Alcatel MBI5
ERICSSON
NWXXXX Area: Langkawi
N/A
2
NWXXXX Building Height(m): -
TELUK EWA Structure Height(m): 45
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 21/40
Site Requirements
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
3.0
3.1 Feeder Data
Total no. of feeders (pcs)
Type of feeders
Feeder lengths (m)
Comments : All cells need MHA
3.2 CABLING
Cable required
Comments :
3.3 Antenna Support Detail
Type of antenna support : Special bracket
No. of H-Boom : -No. of G.I. Pipe : 3
Length of G.I. Pipes (m) : 2m
Other Special Bracket :
Comments : The antennas located below existing 2G antennas.
60
60
120 360TOTAL 120120
60
Cable Lug / 35mm
Length Needed
7m
1 5/8" 1 5/8"1 5/8"
2 62
Cell 1
2
Cell 3Cell 2 TOTAL
180
Rx 60 180
60
60
Tx
NEW SITE REQUIREMENTS
7m
DDF to DF Coax / 3C 2.5V Siemen Male 5m
Node B to MGB Grounding / 35mm
Cabl e Cabl e ty pe / s ize Con nec tor t yp e / si ze
Node B E1 to DF Coax / 3C 2.5V -
Node B to Breaker Grounding / 35mm Cable Lug / 35mm 12m
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 22/40
Site Requirements
Survey Date : 14 June 2007
Project: Celcom 3G Phase 2, Northern Region, MalaysiaCelcom (M) Bhd.
Site: NWXXXX TELUK EWA
3.4 OTHERS
Comments :
3.5 POWER SUPPLY SYSTEM
Rectifier
Make Link Model Vout Iout
Battery Installed : Power Lift L400
Capacity : 6V-162Ah
Banks : 2
Type / Model : Power Lift L400
Comments :
Breaker
Used: 7
Required:
Used:
Free:
Required: 1
Free: 9
No
No
No
Yes
No
Yes below the proposed inlet
Yes Huawei inlet
Capacity
Yes
14.254.4E22
Lightning Protection
CommentExisting Required
Yes No
BTS Location Cabin Cabin
Cable Inlet
AC Ear th ing Busbar Yes
DC Earthing Busbar Yes
MGB Yes
Swichtec
Cable Ladder
Cabin Size 7340X3680
Plinth Size N/A
No
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 23/40
Site Name:Site ID :Existing 2G Site Name:Existing 2G Site ID:Co-locate Operator: Cluster No:
Version:Lat (N-WGS 84- Decimal):Lon g (E-WGS 84-Decimal):
Node B room Type: Node B Type:Node B Configuration:
Transmission Type on site:
Cell Site RF Configuration
Ant enna Heigh t (mi d. o f ant ) Ant enna Direc tio n (deg)Electrical TiltMech. TiltCable Length (m)
Cable Type (inch)
MHA (Y/N)
06 - 25 - 2.899 - 45 - 29.7
Others:
Sector 2 : To cover main road to Padang Lalang, Lafarge Factory area, Lafarge Perumahan B,Kraftangan, kampung area
Sector 3 :To cover main road to Datai, Kampung Tlk Ewa, kampung area
Comment/ Problem:
Sector 1 :To cover main road to Padang Lalang, Lafarge Factory area, Lafarge Perumahan A, PetronasPoint, Jetty Tlk Ewa
1Y Y Y
BOOMHeight (m) 2 2 2Mount
Type BOOM BOOM
No of Pole/ Tripod 1 1
Structure type 3 legged tubular 3 legged tubular 3 legged tubular
60 60 60
1 5/8" 1 5/8" 1 5/8"
2 2 20 0 0
42.5 42.5 42.550° 120° 210°
APXV18-206516Beam width (deg) 65 65 65
Ant enna Type Model Number APXV18-206516 APXV18-206516
Sector 1 Sector 2 Sector 3
1+1+1
ERICSSON
Ams l(m): 74
Cabin HUAWEI Indoor
Phase: 2
NWXXXX Area: LangkawiN/A
NWXXXX Building Height(m): -TELUK EWA Structure Height(m): 45
Technical Site Survey Report (Proposed Antenna Location)
TELUK EWA Survey Date: 14/06/2007
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 24/40
SECTORIAL RF VIEW
Sector 1 50° degree
Sector 2 120° degree
Sector 3 210° degree
NEW SITE RF PHOTO
La Farge Cement Factory
Petronas Oil Tankers
Housing
Housing area
Kampung Ewa Main road to Datai
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 25/40
PANORAMIC VIEW
View at 0°
View at 40°
View at 80°
NEW SITE RF PHOTO
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 26/40
PANORAMIC VIEW
View at 120°
View at 160°
View at 200°
NEW SITE RF PHOTO
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 27/40
PANORAMIC VIEW
View at 240°
View at 280°
View at 320°
NEW SITE RF PHOTO
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 28/40
Existing Site Pictures Survey Date : 14 June 2007
Si te: NWXXXX TELUK EWA
Photo 1 : Site View
SITE PICTURES
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 29/40
Existing Site Pictures Survey Date : 14 June 2007
Si te: NWXXXX TELUK EWA
SITE PICTURES
Photo 2: Antenna Location.
.
Photo 3: BTS Location
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 30/40
Existing CME Survey Date : 14 June 2007
Si te: NWXXXX TELUK EWA
Photo 1 : Existing DB
Photo 2: Rectifier
SITE PICTURES
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 31/40
Existing CME Survey Date : 14 June 2007
Si te: NWXXXX TELUK EWA
SITE PICTURES
Photo 3: Battery
Photo 4: Existing MGB.
at top of tower
at bottom of tower
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 32/40
Existing CME Survey Date : 14 June 2007
Si te: NWXXXX TELUK EWA
SITE PICTURES
Photo 5:MGB inside Cabin
Photo 6 : Breaker
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 33/40
Existing Tx Survey Date : 14 June 2007
Si te: NWXXXXTELUK EWA
Photo 1 : Microwave.
Tx Rack
SITE PICTURES
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 34/40
New Requirement Survey Date : 14 June 2007
Si te: NWXXXX
Photo 1 : Node B Location
Photo 2 : proposed new Feeder Inlet and MGB
SITE PICTURES
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 35/40
New Requirement Survey Date : 14 June 2007
Si te: NWXXXX
SITE PICTURES
Photo 3 : Proposed DDF Box Location beside Tx Rack
Photo 4 : To rearrange existing feeder to free up space for 3G feeders
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 36/40
New Requirement Survey Date : 14 June 2007
Si te: NWXXXX
SITE PICTURES
Photo 5 : Proposed Antenna Location
Photo 5 : Site Top view
Celcom
Digi
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 37/40
BILL OF QUANTITY SITE NWXXXX
NO TYPE ITEMS ART NO. PACKING REQUEST SUPPLY
IRON WORK Fill in your requested item(s)1 SPECIAL BRACKET SET
2 6m Tripod NA SET
3 6m BOOM N/A PC
4 WALL BRACKET N/A SET
POWER / RF CABLES & ACCESSORIES1 Power Cable METER
2 METER
3 AC ARMOURED CABLE, 4CORE, 16mm AC.ARM.4C.16mm METER
4 PVC/PVC AC CABLE 5 CORE, BLACK, 10mm 5C/10mm METER
5 CABLE TIE 4" (WHITE) CBL. TIE -W-IND-4" PC
6 CABLE TIE 8" (WHITE) CBL. TIE -W-IND-8" PC7 CABLE TIE 14" (WHITE) CBL. TIE -W-IND-14" PC
8 CABLE TIE 14" (BLACK) CBL. TIE -W-OUD-14" PC
9 7/8" COAXIAL CABLE EC5-50 METER
10 1/2" COAXIAL CABLE LDF4-50A METER
11 TX JUMPER CABLE (716M - 716M), 2 MTR F4A-PDMDM-2M PC
12 RX JUMPER CABLE (716M - NM), 2 MTR F4A-PNMDM-2M PC
EARTHING SYSTEM 1 COPPER BARE WIRE, 35MM, MULTI STRAND N/A METER
2 ANDREW CONNECTOR EARTHING KIT (INDOOR) 244495 PC
3 ANDREW FEEDER EARTHING KIT (OUTDOOR) SGL5-06B1 PC
CONNECTORS1 RFS ANGLE ADAPTER N-TYPE (MALE TO FEMALE) 15852401 PC
2 H+S BNC CONN. (JACK FULL), 75 OHM, FOR RG59 21BNC-75-4-4 PC
3 RFS 7/16 FEMALE CONNECTOR FOR 7/8" CABLE 15570560 PC
4 H+S N-MALE CONNECTOR FOR 7/8" CABLE 11N-50-23-10 PC5 H+S N-MALE CONNECTOR FOR 1/2" CABLE 11N-50-12-10 PC
6 H+S TNC-MALE TO BNC FEMALE ADAPTOR 33-TNC-BNC50-1 PC
7 H+S N-MALE TO N-MALE ADAPTOR 32N-50-0-2 PC
8 RFS FEEDER COUPLING (SPLICER) 155 730 60 PC
MISCELLANEOUS ITEMS1 AC TRUNKING, 2" X 2", ORANGE C/W ACCESS N/A PC
2 METAL CABLE TRAY, 4" X 1", H.D.G., C/W ACCESS N/A PC
3 CABLE LUG 35MM N/A PC
4 CABLE LUG 150MM N/A PC
5 C-CLAMP (C-TYPE) COMPRESSED FOR 35MM N/A PC
6 3M COOL SHRINK N/A PC
7 CABLE GLAND (FEEDER THROUGH) N/A PC
8 3M ELECTRICAL TAPE, SUPER 33+, 3/4 X 66' 6132 PC
9 3M ELECTRICAL PUTTY , SCOTCHFILL, 1 1/2" X 60" 15140 PC
10 FEEDER CLAMP (2 IN 1) N/A PC11 FEEDER CLAMP (3 IN 1) N/A PC
12 PVC TRUNKING (GREY), 4" X 2" X 1.8M 7 LENGTH
13 SYW RAWL PLUG (M6X450MM) PC
14 SYW RAWL PLUG (M12) with rod PC
15 SYW RAWL PLUG (M12) w/o rod PC
TOTAL COST (FOR INSURANCE PURPOSES)
Requester: _________________________ Checked By: _________________________
(SIGNED & STAMPED) (SIGNED & STAMPED)
TELUK EWA
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 38/40
A. SITE DETAILS
TELUK EWA
1 . X OWN TRANSMISSION SOLUTION
X MICROWAVE VSAT FIBER OPTIC
REMARKS
REMARKS :
2 . LEASED LINE
TM LEASED LINE POI/POP : . 2 E1
3 E1
REMARKS :
C . ADDITIONAL REQUIREMENT FOR TRANSMISSION SOLUTION.
1 . CME
TRM/TOC DC POWER SUPPLY ( Pls specify : )
TRIPOD SHELTER ( Pls specify : )
PLINTH DDF
REMARKS :
Prepared by,
E1 SHARING ( MAXIS / DIGI) POI/POP : .
SITE B
TM PDG LLG
INSTALLED FREEUSED RESERVED
TLK EWA
SITE A
SITE NAMESITE IDRNC HOMENODE B TYPE
TSS TRANSMISSION CHECKLIST FOR 3G
Isriadi Ngaliman 019-3116551
B . TRANSMISSION MEDIA FOR NODE-B CONNECTION.
REGIONSURVEY BYSURVEY DATE
NORTHERNMOHD NIZAM NWXXXX
Verify by, (Name, TX Region. HP num)
14/06/2007INDOOR
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 39/40
8/19/2019 SDP 3G SR Teluk Ewa
http://slidepdf.com/reader/full/sdp-3g-sr-teluk-ewa 40/40