    OPERATION

    PREPARATION AFTER MAINTENANCE

    Check the precipitator internals and remove the

    tools and other foreign materials.

    Check all the insulators visually.

    Inspect the rapping motors and top-up with oil.

    Run the rapping motors and ascertain that they

    function normally.

    Check that the heating elements.

  • 7/31/2019 O&amp_M mech

    17/27

    Check the dielectric strength of transformer

    oil

    Megger and test all the fields on air load.

    Ensure that the ash handling system is

    working properly.

  • 7/31/2019 O&amp_M mech

    18/27

    START UP PROCEDURE

    Switch on the heating elements at least 24

    hours before the start up of the boiler.

    Switch on the rapping mechanisms as soon as

    the boiler is lighted up.The HVR shall not be energised until the gas

    temperature is above 100C.

  • 7/31/2019 O&amp_M mech

    19/27

    OPERATIONAL CHECKS

    Check the normal function of Precipitator

    Logging of readings hourly.

    Record the failures and outages.

  • 7/31/2019 O&amp_M mech

    20/27

    SHUTDOWN PROCEDURE

    Switch off the fields when the gas temperature isbelow acid dew point.Continue the operation of the rapping motors in

    intermittent mode for 4hrs.

    Evacuate the ash from all hoppers.The access doors may be opened after following

    the interlock sequence.

  • 7/31/2019 O&amp_M mech

    21/27

    SHUTDOWN INSPECTION

    Inspect the internals for :

    Snapped or loose wires.

    Excessive ash accumulation.

    Dislocation of shock bars, shock bar guides and CE

    Rapping system, hammers, plain bearing shaft etc

    Insulators

    Disconnecting switch and contacts.

    All heating elements

    Any other abnormality.

  • 7/31/2019 O&amp_M mech

    22/27

    MAINTENANCE

    GENERAL

    Ensure the guide vanes, splitters, deflector plates

    on the gas distribution screen as per original.

    R , .

    Inspect for corrosion, wear and tear of ,

    , .

    .

  • 7/31/2019 O&amp_M mech

    23/27

    MECHANICAL SYSTEM

    (i) Collecting Electrode system

    Check the alignment of CE, shock bars and

    guides.

    Replace the shock bars/shock pads if worn out

    excessively.

    Check the rapping mechanism if dust build up is

    excessive.

    Tack weld all the fasteners after tightening. Care

    should be taken not to tack weld the HSFC bolts if

    used for CE and shock bars

  • 7/31/2019 O&amp_M mech

    24/27

    (ii) Emitting Electrode system

    Check the emitting electrodes forexcessive electrical erosion and snapping.

    Remove the eroded/snapped electrodes, if

    any.

    Care shall be taken not to disturb the

    healthy electrodes while replacing with

    new electrodes.

    Wherever the access is difficult, the

    intervening electrodes may be unhooked

  • 7/31/2019 O&amp_M mech

    25/27

    , .

    .

  • 7/31/2019 O&amp_M mech

    26/27

    Insulators

    The insulator shall be inspected during shutdown for cleanliness, cracks and rigidity of metal

    parts

    Dusty insulators should be cleaned with Carbon

    tetrachloride / Petrol in both inner and outer

    portions.

    Cracked insulators should be replaced.

    Support insulators shall be replaced, if required,

    with the help of lifting tool and alignment jig as

    per procedure.

  • 7/31/2019 O&amp_M mech

    27/27

    AIR LOAD TEST AFTER MAINT.,

    Please ensure:

    All foreign materials are removed.

    All heaters are energized

    Meggering of fields ( around 500 Meg Ohms)

    Charge the fields with still air load and ensure:

    Fields building up up to rated current and kV without

    sparking. Incase of sparking attend the discrepancy and

    repeat the test.

    Air load test is a must after every maintenance of fields.