1 FIRE DETECTION AND ALARM SYSTEMS

Transcript of FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa...

Page 1: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

1

FIRE DETECTIONAND ALARM SYSTEMS

Page 2: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

2

Polon-Alfa Spółka z ograniczoną odpowiedzialnością Sp. k. (limited partnership company) is a medium-sized Polish

enterprise that has been involved in research & development and production activity in the fire detection and alarm system

business for over 50 years. The company’s beginning dates back to the fifties of the previous century when a laboratory

focused on ionisation radiation was established. This workshop created, as the first one in Poland and the third in the world,

an ionisation smoke detector in 1962. Its main activity was focused on manufacturing of nuclear radiation measurement

devices which are still a part of the company’s production. In the course of time, the firm main business interest was set on fire

detection and alarm systems and therefore nowadays Polon-Alfa is the main manufacturer of those devices in Poland and one

of the leading ones in Europe.

Polon-Alfa’s main asset is a team of qualified, well trained and experienced engineers who are able to work out and

develop very comprehensive state-of-art solution. The company’s assortment is steadily extended and enhanced: nowadays

it comprises both conventional and addressable fire detection systems as well as control panels suitable for smoke exhaust

controlling installations.

Most attention is given to the product high quality – therefore the company obtained the ISO 9001 quality management

system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with

EC-Conformity Certificates that confirm that the goods meet the European Standards requirements (in particular the EN 54

standard). The company possesses highly advanced research and quality control equipment including a fire test chamber, which

gives a testing possibility in real fire conditions. As the factory specialises in design and production of equipment used in various

important fields, some devices are attested by ATEX certificates that confirm their suitability in explosive dangerous conditions.

Since 2002 the company has the NATO NCAGE code and approval.

The innovative fire protection systems created and developed by the company have been proved in small premises

such as households and small offices or shops as well as in much bigger ones: hotels, office and historical buildings, industrial

factories, etc. The devices marked with the POLON-ALFA logotype are installed and secure premises mainly in Poland but also in

foreign markets like Ukraine, Lithuania, Spain, Italy, Turkey, Bulgaria and Kazakhstan. The reference list includes such objects as the

Warsaw Uprising Museum, Łazienki Palace in Warsaw, University Children’s Hospital in Cracow, British-American Tobacco factory

in Augustów, Mercure hotels and many others.

Dynamic product development assured by the young qualified engineering staff and supported by five decade

experience confirm that the workers may feel proud of their products highest level expressed in the phrase: POLON-ALFA. LATEST TECHNOLOGY. HIGHEST QUALITY.

Page 3: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

3

Overview

The POLON 6000 control panel with a distributed architecture

The addressable, interactive POLON 6000 fire alarm system is a set of latest technology equipment, designed for very fast detection and signaling of fire, precise indication of fire origin, control of fire protection safety devices, and information of appropriate interven- tion services or building guards about fire. It enables protection of mid-size, large and very large facilities, especially so called “intelli- gent” buildings with huge amount of fire protection safety devices. POLON 6000 can be easily integrated with many existing building management systems. Due to its specific features it enables to ar- range perfect set of necessary devices, well-fitted to building con- ditions.The POLON 6000 system is based on newly designed control panels with distributed architecture and new set of line elements (6000 se- ries), supplemented with line elements of series 4000 with changed software version.All devices of the POLON 6000 system meet requirements of the latest edition of EN 54 European Standards.

The POLON 6000 control panel was designed based on the idea of a module device with a distributed architecture. It consists of many unified modules of various types, installed inside standardized ca-binets. Cabinets can be arranged as separate units or combined in sets (so called nodes) and can be located in different places of pro-tected building, even if those locations are distant. All modules wi-thin one node and nodes between themselves are connected with a common, doubled (redundancy) digital communication bus.

Each control panel can be flexibly assembled with modules and no- des well-fitted to individual building requirements. Such solution enables the arrangement of the control panel equipment, installed in required locations. This provides maximum optimization of the system, reduction of cost of installation while the system is still extremely reliable and functional. All that is possible thanks to im- plementation of doubled main processor controllers, communica- tion buses and cable connections between nodes.The POLON 6000 control panel consists of the PSO-60 panels with 10’’ touch screen, functional modules: detection lines MLD-61 and MLD-62, input-output modules MKS-60, relay outputs MPK-60, si- gnalling outputs module MWS-60, high current relay outputs MPW- 61, supervision inputs MWK-60, supply modules MZP-60 and trans- mission modules MTI-61, MTI-62, MTI-63.PSO panels and modules are installed inside the cabinets with stan- dard dimensions, which can be mechanically connected. A set of such mechanically connected cabinets create a control panel node. The control panel has to have at least one node in which main con- trol panel PSO-60 (having number 1) is installed. This is the “main node” of the control panel. There is always only one “Main node” in the system. The rest of elements (modules) of the control pa- nel is configured in form of external nodes which are connected to the “main node”. The communication between nodes is provided by means of doubled cable connection (RS-485) or doubled fiber optic cables. Each node shall be equipped – depending on the size of node and expected current consumption – with one or more supply mo-dules. Each node can contain line modules with connected de- tec-tion lines, input-output modules for direct control or supervision of fire safety devices. In each external node the PSO-60 panel can be implemented, acting as the parallel operation panel.

Page 4: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

4

PRODUCT DESCRIPTION

PSO-60

The PSO-60 is an operator panel equipped with 10” touch screen (800x600 pixels) and key-pad integrated with main controller MCS-60 and redundant controller MSR-60. It is installed in doors of OM-62 cabinet or can operate as a remote panel fitted in small cabinet OS-61. The remote panel (PSO-60 and OS-61) marked as WPO-60 is equipped with two transmission modules MTI-61 and MTI-62 but has no power supply unit.

MKS-60

The module is equipped with:- Two potential-free relay outputs with max load 1 A/30 V,- Two potential outputs (signaling lines) with 0,5 A/24V,- Two low voltage monitoring inputs.The module is fail-safe ready and the position of the relay or its operation in case of fault can be programmed. Inputs and outputs are equipped with external line continuity monitoring circuits. Monitoring input can be programmed as 2-states (quiescent and action) or 3-states (quiescent, action 1 and action 2). States are identified by different resistance of the line.

MPK-60

The module is equipped with 4 relay potential-free outputs with current load up to 1 A/30 V. The module is fail-safe ready and the position of the relay or its operation in case of fault can be programmed. Outputs are equipped with external line continuity monitoring circuits.

MWS-60

The module is equipped with 4 signaling lines with 0,5 A/30 V. Outputs are equipped with external line continuity monitoring circuits.

MWK-60

The module is equipped with 8 resistance monitoring inputs. Inputs are equipped with exter-nal line continuity monitoring circuits. They can be programmed as 2-states (quiescent and action) or 3-states (quiescent, action 1 and action 2). States are identified by different resi-stance of the line.

MPW-61

The module is equipped with:- Two high voltage potential-free relay outputs with 5 A/230 V AC,- Two monitoring inputs.Inputs and outputs are equipped with external line continuity monitoring circuits. Moni-toring input can be programmed as 2-states (quiescent and action) or 3-states (quiescent, action 1 and action 2). States are identified by different resistance of the line.

MD-60

The module is equipped with the controller and the thermal printer mechanism.

FIRE CONTROL PANEL POLON 6000

Page 5: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

5

PRODUCT DESCRIPTION

MZ-60-150MZ-60-300

Power supply modules consist of power unit and supervising unit MZP-60. Two versions are available: 150 W and 300 W (max current load is 5 A/24 V or 10 A/24V). Power supply modu-les are complete units being installed inside control panel’s cabinets. Modules are equipped with:- Two potential-free relay outputs with 1 A/30 V,- Two potential outputs to power auxiliary devices with the total current load of 0,5 A (not programmable),- Output for batteries and temperature probe.

OM-61OM-62OS-61OA-61OA-62

Components of the control panel can be installed in several types of cabinets:- OM-61 – dedicated for installation of functional modules, power suppliers and batteries,- OM-62 – dedicated for installation of the operator panel PSO-60, printer, MD-60 and func-tional modules,- OS-61 – dedicated for installation of the operator panel PSO-60 only. This configuration is marked as WPO-60 – remote operator panel,- OA-61 – battery container, 2 x 12 V, max 134 Ah,- OA-62 – battery container, 2 x 12 V, max 90 Ah.Dimensions (L x H x W)OM-61, OM-62 (main cabinet) 445 x 455 x 177 mm OS-61 (remote panel cabinet) 350 x 336 x 96 mmOA-61 (battery container) 445 x 682 x 199 mmOA-62 (battery container) 445 x 522 x 199 mm

MTI-6X

Transmission modules MTI secure the data bus of the control panel.MTI-61 is a transmission module without separation. The module is used for connection of transmission channels between cabinets within single node. It contains also two power sup-ply lines.MTI-62 is a transmission module with galvanic isolation. The module is used for connection of transmission channels between nodes. The maximum distance is limited to 1200 m.MTI-63 – is a transmission module dedicated for the connection of transmission channels between nodes using fiber optic cable.

SM-60

According to the panel configuration following elements can be used:- SM-60 – assembly frame for max four functional modules,- Assembly brackets WP-61/WL-62 and WP-63/WP-64 dedicated for installation of assembly frame either at the top or at the bottom part of the cabinet,- cables with different length for communication and power supply distribution within the node.

WP-61/WL-62WP-63/WL-64

Mounting brackets for assembly frames instalation

Conetion cables

LK-61-035 Connection wire for SM-60 (35cm)LK-61-050 Connection wire for SM-60 (50cm)LK-61-070 Connection wire for SM-60 (70cm)LK-61-090 Connection wire for SM-60 (90cm)LK-61-320 Connection wire for WPO-60 (320cm)LK-62-035-050 Wire splitter for SM-60, MTI-xx and MZ-60-xxx (35/50cm)

Key NODE parameters

Power supply:- mains voltage 230V +10% - 15% / 50 Hz- batteries 2x 12V from 17 Ah to 134 AhNode components max quiescent current consumption:PSO-60 450 mAMLD-61 173 mAMLD-62 153 mAMZP-60 45 mAMKS-60, MPK-60, MWS-60, MWK-60, MPW-60 15 mAMD-60, MTI-62 35 mAMTI-63 70 MaConfiguration of detection lines 6000/4000 protocoleResistance of detection line max 2 x 100 OhmCapacity of detection line max 300 nFDetection line load max 50 mAAlarming modes 15 + individualOperation temperature range from -5oC to +40oC

Page 6: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

6

PARAMETERS DUO-6046 DUT-6046 DTC-6046 TUN-6046 DOP-6001ROP-

4001M(H)

Applied sensor IR, UV

optical smoke

IR, UVoptical smoke,

heat

IR, UV, CO, optical smoke, heat, carbon

monoxide

heatbeam smoke

detector-

Maximum quiescent mode current 150 µA 150 µA 150 µA 170 µA 300 µA 140 µA

Detectable test fires TF1 to TF5,TF7 to TF9

TF1 to TF9 TF1 to TF9 N/ATF1 to TF5,

TF7, TF8N/A

Numer of modes of operation 16 6 2558

(temp. classes)3 -

Operation temperature range -25°C ÷ +50°C -25°C ÷ +50°C -10°C ÷ +50°C

-25°C ÷ +50°C-25°C ÷ +65°C

for class B, BS, DR

-25°C ÷ +55°C-25°C ÷ +55°C (ROP-4001M)-25°C ÷ +70°C

(ROP-4001MH)

PARAMETERS EKS-6044 EKS-6022 EKS-6004 EKS-6040 EKS-6202 EKS-6400 EKS-6222P UCS 6000

Maximum current consumption

240 µA 220 µA 240 µA 210 µA 250 µA 230 µA 550 µA

see page 14

Number of inputs and/or outputs

4 inputs4 outputs

2 inputs2 outputs

0 inputs4 outputs

4 inputs0 outputs

2 HV inputs2 outputs

4 HV inputs 0 outputs

2 LV/2 HV inputs

2 HV outputs

Max output current load

2 A/230 V/62.5 VA

2 A/230 V/62.5 VA

2 A/230 V/62.5 VA

N/A2 A/230 V/

62.5 VAN/A

12 A/230 V/2.76 kVA

IP Rating IP 66 IP 66 IP 66 IP 66 IP 66 IP 66 IP 66

Operating temperature range

-40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +85°C -40°C ÷ +70°C

ADDRESSABLE FIRE DETECTORS

INPUTS/OUTPUTS ELEMENTS

Page 7: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

7

PARAMETERS ADC-4001M SAL-4001 SAW-600X ACR-4001 DUR-4047 ROP-4007(H)

Max. quiescent current consumption

16 mA(depends on the

mode of operation)600 µA 150 µA 6 µA 80 µA 140 µA

Max. side line current consumption

2 mA(depends on the

mode of operation)N/A N/A N/A N/A N/A

Number of modes of operation

6 3 16 sequences N/A 3 N/A

Test fires N/A N/A N/A N/A TF1 to TF5, TF8 N/A

Max sound output dB

N/A 100 dB 103 dB N/A N/A N/A

Operation temperature range

from -25 °C up to +55 °C

from -10 °C up to +55 °C

from -25 °C up to +50 °C

from -25 °C up to +55 °C

from -25 °C up to +55 °C

ROP-4007 from -25 °C to +55 °C

ROP-4007(H) from -40 °C to +70 °C

OTHER ELEMENTS

DESCRIPTION TECHNICAL DATACM-180-29 converter is designed for conversion of signals from PMC-4000 protocol which is implemented in addressable control panels made by PO-LON-ALFA to ModBus RTU protocol. The ModBus RTU protocol is often used in BMS systems (visualization, moni-toring, etc.) as a common software platform for integration of many security systems in a building.

Power supply from 7 to 30 V DCPower consumption without load 2 VASoftware memory EEPROMRS 232 max wire length 15 mRS 485 max wire length 1200 mInstallation using rail brackets acc. PN/E-06292

or DIN EN 50 022-35Operation temperature range from -30 °C to +60 °CDimensions 108 x 53 x 58 mmMass 0.12 kg

CM-182-2 converter is designed for conversion of signals from PMC-4000 protocol which is implemented in addressable control panels made by PO-LON-ALFA to BACnet MS/TP protocol.The BACnet MS/TP protocol is often used in BMS systems (visualization, mo-nitoring, etc.) as a common software platform for integration of many secu-rity systems in a building.

Power supply from 7 to 30 V DCPower consumption without load 2 VASoftware memory EEPROMRS 232 max wire length 15 mRS 485 max wire length 1200 mInstallation using rail brackets acc. PN/E-06292

or DIN EN 50 022-35Operation temperature range from -10 °C to +60 °CDimensions 93 x 52 x 58 mmMass 0.12 kg

GSM service transmitter TSG-1 is a device that enables to send SMS infor-mation about all events recorded by the control panel made by POLON-ALFA. It can also monitor any device which is equipped with potential free relay output. The transmitter uses GSM network and SIM card putted inside the device. The computer application dedicated for programming of the trans-mitter enables for programming up to 5 different mobile phone numbers and for categorization of messages send to each number.

GSM frequency 850/900/1800/1900 MHzAntenna connection SMAPower supply from 5 to 30 V DCMax. current consumption 400 mAConnection with addressable panels RS-232Communication protocol with control panels PMC-4000Inputs W1, W2 (triggered by short to ground)Connection with the computer USB (mini USB in transmitter)Operation temperature range -30 °C to +75 °CDimensions 89 x 60 x 30 mmMass 0.1 kg

Page 8: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

8 9

number of all modules 900

number of modules of one type 99

number of line modules 198

number of addressable lines/loops 396

number of addressable elements installed 99000

number of line elements on one loop 250

number of all possible control outputs 64000

number of control outputs on one loop 256

number of non-potential/potential control outputs on the functional modules 1000/600

number of all supervision inputs 64000

number of supervision inputs in one detection loop 256

number of supervision inputs in functional modules 1200

POLON 6000 DISTRIBUTED FIRE DETECTION AND ALARM SYSTEM

Page 9: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

10

POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM

The POLON 4000 addressable interactive fire alarm system is a set of the newest generation units designed for detection of a fire in its earliest stage, sending an alarm signal to appropriate emer-gency services (e.g. Fire Brigades), and controlling external fire protection units. POLON 4000 is intended for protection of mid-size, large and very large buildings. The newest signal transmission protocol in detection lines is a cutting-edge solution that enables interactive co-operation between line elements and the control panel as well as between each other. This type of fire detection system philosophy guarantees unique opportunities of very pre-cise, automatic analysis of phenomena occurring in the protected facility. Mutual information exchange carried out by fire detectors provides necessary information as early as at the beginning fire development stage, during a phase, in which the classic fire alarm systems used until now were not able to react. Such early collection of information ensures precise analysis of observed occurrences, enables to distinct a fire hazard state from a short-term interference phenomenon and thus a well-balanced, verified decision may be taken by the fire detection system.Fire alarm control panels can operate separately in installations of up to 1,000 line elements, or in hierarchical, ring structure networks in the case of large or scattered facilities. In this situation, the number of line elements connected to the system (POLON 4900 fire alarm control panels) can exceed 31,000. The system is supplemented by the POLON 4500 4-zone automatic fire extingu-ishing control panel. The control panels can be manufactured in different language versions.

PARAMETERS POLON 4100 POLON 4200 POLON 4500 POLON 4900

Number of detection lines 2 4 4 4 (optionally 8)

Number of addresses per detection line 64 64 127 127

Number of detection zones 128 256 512 1024

Number of extinguishing zones – – 1, 2, 3 or 4 -

Number of interoperating elements- ADC-4001M- EKS-4001- EWS-4001 (max. 20 pcs. per loop)- EWK-4001 (max. 20 pcs. per loop)- SAL-4001- UCS 6000 (max. 20 pcs. per loop)

pursuant to current draw4040404040

pursuant to current draw5050505050

pursuant to current draw2508080

25080

pursuant to current draw250100100250100

Allowable line elements current draw from detection line:- loop resistance at 2x100 Ω- loop resistance at 2x75 Ω- loop resistance at 2x50 Ω

20 mA22 mA50 mA

20 mA22 mA50 mA

20 mA22 mA50 mA

20 mA22 mA50 mA

Number of programmable outputs:- non-potential contacts 1 A/30 V- signalling lines 1.0 A/24 V- signalling lines 0.5 A/24 V- signalling lines 0.1 A/24 V

2–1–

8–11

813–

16–26

Number of monitoring general inputs 2 2 4 8

Available alarm variants number 17 1717 (3 of them for automatic

extinguishing)17

Network operation option no no 31 31

Maximum power consumption from battery in quiescent mode

0.25 A 0.4 A 0.65 A 0.6 A

Maximum 2 x 12 V battery cluster capacity

max. 22 Ah 17 ÷ 38 Ah 38 ÷ 180 Ah 17 ÷ 90 Ah

Dimensions L x H x G [mm] 420 x 384 x 115 393 x 483 x 190 536 x 492 x 218 536 x 492 x 218

FIRE ALARM CONTROL PANELS - POLON

Page 10: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

11

PARAMETERS DUR-4046 DOR-4046 DOT-4046 DPR-4046 TUN-4046 DOP-6001

Applied sensor UV

scattering optical IR

scattering optical IR scattering optical

+ heat

IR scatteringoptical

+ IR flameHeat

Opticalabsorption

Maximum quiescent mode current

150 µA 150 µA 150 µA 170 µA 150 µA 300 µA

Detectable test fires TF1 to TF5, TF8 TF2 to TF5 TF1 to TF6, TF8 TF1 to TF5, TF8 not applicable TF1 to TF5

Operationmode/sensitivity (optional)

1-normal 2-increased 3-decreased

1-normal 2-increased 3-decreased

7 modes 1 mode of both sen-sors interoperation

8 modes relevant to detector’s classes

18 %30 %50 %

Operation tempera-ture range

-25°C ÷ +55°C -25°C ÷ +55°C from -25°C to +50°C for A1R +65°C for BR

-25°C ÷ +50°C from -25°C to +50°C class A +65°C class B

-25°C ÷ +55°C

ADDRESSABLE FIRE DETECTORS

OTHER DEVICES

DESCRIPTION TECHNICAL DATAThe TSR-4000 parallel indication terminal is a microprocessor based unit de-signed to interoperate with the POLON 4000 system fire alarm control panels as a remote signalling and operation unit. Up to 16 TSR-4000 terminals may be connected to one control panel. The terminal repeats signals indicated by the connected POLON 4000 system fire alarm control panel, which are alarm and fault messages, disablements, tests and technical alarms. A fire signal can be acknowledged and then the fire alarm can be reset from the terminal level.

Operating voltage:- mains 50 Hz 230 V +10% -15%- reserve battery 2 x 12 V / 7 AhMax. battery current drawin quiescent mode 100 mAAlphanumeric LCD display 4 x 40 charactersOperating temperature range from -5 oC to +40 oCIngress protection IP 30Dimensions 314 x 368 x 106 mm

The EKS-4001 and EKS-4001W input/output devices are designed to actuate – after receipt of a signal from the control panel – alarm and fire-protection devices, such as: signalling devices, fire dampers, fire-protection doors, etc. The fire security device actuation is performed with usage of relay contacts. They enable control over the efficiency and proper activation of the moni-tored unit. The EKS-4001 input/output device is an interchangeable module with two angle connectors, which is installed in single, dual or quadruple appropriate casings.

Current draw in quiescent mode < 165 µA High voltage relay output (4001) 2 A/30 VHigh voltage relay output (4001W) 0,25 A/230 VMonitoring line current max 0.6 mADelay in relay operation 2 s, 30 s, 60 s, 90 sNumber of monitoring inputs 2Cable inlets per 1 EKS:- detection line wires 2 gland seals PG7- monitoring or control wires 1 gland seal PG9 per 1 EKSOperating temperature range from -25oC to +55oCIngress protection IP 65

The EWK-4001 addressable multi-input supervising element is designed for monitoring of external fire protection equipment (e.g. fire proof doors, fire dampers). The device is equipped with eight independent monitoring inputs routed to a junction block.

Current consumption ≤ 150 µANumber of monitoring inputs 8Monitored input initiation non-potential change-over NO or NC contactMax. number of elements in one detection line 20 Operating temperature range from -25oC to +55oCIngress protection IP 65Dimensions with glands 175 x 146 x 75 mm

The EWS-4001 addressable multi-output controlling device is designed to control different fire-fighting automatic equipment, in particular for swit-ching-on pre-fire warning sound systems and synoptic signs. The device is equipped with eight independent relays with non-potential change-over contacts.

Current consumption ≤ 150 µANumber of output relays 8Type of relay contact change-overLoad capacity of relay contact 2 A/30 VOperating temperature range from -25oC to +55oCIngress protection IP 65Dimensions with glands 250 x 195 x 75 mm

Page 11: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

12

IGNIS CONVENTIONAL FIRE DETECTION AND ALARM SYSTEM

The IGNIS 1000 fire detection and alarm system is a set of units based on micro-processor operated fire alarm control panels with capacity of 4, 6, 8, 16, or 24 non-addressable detection lines. These control panels are designed for installation in small and medium sized buildings. The modern structure of the above said units enables to create a complex and functional fire alarm system. All control panels comply with the EN 54-2 European standard. The specialized IGNIS 1520M control panel enables control of the automatic fire extinguishing process using various extinguishing agents and methods.

The control panels interoperate with the 40 model range conventional fire detectors. The control panels can be manufactured in various language versions.

PARAMETERS IGNIS 2040 IGNIS 1080 IGNIS 1240 IGNIS 1520M

Number of detection lines4 to 6

(2 programmable)8

16 or 24after extension

2

Number of extinguishing zones - - - 1

Maximum number of detectors per line:- spot detectors- beam detectors- intrinsically safe detectors

321

pursuant to manual

321

pursuant to manual

321

pursuant to manual

321

pursuant to manual

Number of MCP per line 10 10 10 10

Allowable detection line resistance

2 x 100 Ω 2 x 120 Ω 2 x 120 Ω 2 x 120 Ω

Detection line Rk end-of-line resistor

5.6 kΩ ± 5% 0.25 W 5.6 kΩ ± 5% 0.25 W 5.6 kΩ ± 5% 0.25 W 5.6 kΩ ± 5% 0.25 W

Allowable quiescent current of detectors in detection line

2 mA 2 mA 2 mA 2 mA

Number of relay outputs:- of general alarm- of general fault- of zone alarms- potential ones

1 A / 30 V load1 switchable

16–

1 A / 30 V load2 switchable

18–

1 A / 30 V load1 or 2

116 or 24

3 programmable1

2 programmable6

Number of monitoring lines – 4 2 or 3 4 dedicated

Number of lines to alarm devices

2 (programmable) 1 2 or 3 3 dedicated

Admissible alarm devices current

180 mA 140 mA 140 mA 1,0 A

Maximum power consumption from battery in quiescent mode

69 mA 90 mA170 mA/16 lines228 mA/24 lines

90 mA

Maximum 2 x 12 V battery cluster capacity

3,2 ÷ 7 Ah 6,5 ÷ 36 Ah 17 ÷ 36 Ah 6,5 or 7 Ah

Dimensions L x H x G [mm] 311 x 337 x 81 314 x 368 x 106 392 x 482 x 190 314 x 368 x 106

FIRE ALARM CONTROL PANELS - IGNIS

Page 12: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

13

PARAMETERS DUR-40 DOR-40 DOT-40 TOP-40 TUP-40 DOP-6001 PUO-35

Applied sensor UV scattering

optical IR scattering

optical

IR scattering optical + heat

Heat + IR flame Heat Optical

absorption UV Flame

Maximum quiescent mode current

60 µA 60 µA 60 µA 90 µA 40 µA 5 mA/2.2 mA 100 µA

Detectabletest fires

TF1 to TF5, TF8 TF2 to TF5 TF1 to TF6, TF8 TF1, TF4 to TF6 N/A TF1 to TF5 TF1, TF4 to TF6

Heat sensor class – – A1 A1R A1R – –

Operation mode/sensitivity(optional)

– – 3 modes – – 18%, 30%, 50% class 2

Operation tem-perature range

-25°C ÷ +55°C -25°C ÷ +55°C -25°C ÷ +50°C -20°C ÷ +50°C -25°C ÷ +50°C -25°C ÷ +55°C -10°C ÷ +55°C

CONVENTIONAL FIRE DETECTORS

OTHER DEVICES

DESCRIPTION TECHNICAL DATAThe Ex model range fire detectors: DUR-40Ex optical smoke detector, TUN-38Ex universal heat detector and PUO-35Ex flame (UV) detector are designed for use in explosion hazardous premises. Those intrinsically safe detectors provide protection of zones 1 and 2 pursuant to the PN-EN 60079-10:2003(U) standard in buildings, rooms and large spaces with gas and flam-mable liquid vapour hazard. They operate in detection lines of conventional control panel fire alarm systems or in side lines using addressable ADC ada-pters, always behind a proper spark proof separator. The Ex model range fire detectors are spot two-state detectors, which means they can work in two modes: Normal and Alarm.

Max. quiescent mode current- DUR-40Ex ≤ 60 µA- TUN-38Ex, PUO-35Ex ≤ 100 µAAlarm current 20 mA Colour blackDimension: - DUR-40Ex ø115 x 54 mm - TUN-38Ex ø112 x 62.5 x 60 mm- PUO-35Ex ø107 x 60 mm

The G-40 base is designed for mounting 40, 4043 and 4046 model range detectors on ceilings and for connecting detection lines to them. The base can be mounted in the PG-40 base footing in order to increase its tightness in rooms whith water vapour condensation on the ceiling. The base can be additionally equipped with the P-40 masking ring

Diameter of installation cable wires max. 1 mm Dimensions ø 107 x 28.5 mmMass 0.1 kgColour white

The ROP-63 and ROP-63H conventional manual call points are designed to send information about a fire to the interoperating fire alarm control panel by a person who notices the fire and manually actuates the call point. They are B type MCPs.The ROP-63 manual call point is designed to be installed indoors, while ROP-63H call point is designed for outdoor installation. They can be installed insi-de the wall plaster (semi-flushed mounting) or on it, using a masking frame (surface mounting).

Switched contacts resistance < 150 mΩMax. connection wire diameter 0.8 ÷ 1.2 mmIngress protection IP 30/IP 55Operating temperature range: ROP-63 from -25oC to +55oCROP-63H from -40oC to +70oCDimensions 102 x 98 x 46 mm

The WZ-31 alarm indicator is designed for optical repeated indication of the alarm mode of a detector or a group of detectors in the fire alarm system. It can be installed in a conventional or addressable detection line. The device is particularly suited for detectors mounted in a hardly visible or accessible places, e.g. in spaces above suspended ceilings, in cable ducts, etc.

Power supply by interoperating detectorMax. current draw 20 mAMax. cross section of attached wires 1.5 mm²Dimensions ø 49 x 21 mmColour ‘milky’

Page 13: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

14

DESCRIPTION TECHNICAL DATAThe UCS 6000 universal controlling unit is designed for actuation of fire pro-tection devices, used for mechanical or gravitation smoke ventilation (fire dampers, smoke exhaust dampers, etc.) and enables the following:• detection of fire (smoke);• automatic or manual actuation of fire protection devices installed in smoke exhaust systems;• acoustic and optic signalling of the devices operation modes (alarm, fault condition);• automatic monitoring of activation of fire protection devices (servomotors, electromagnets, ventilators, etc.) of smoke exhaust systems;• automatic monitoring of its own modules and the panel circuits;• transmission of main information to master control systems (e.g. POLON 4000 system, IGNIS 1000 system or others) about an alarm mode, faults, pre-sent fire protection devices state.

The UCS 6000 control panel can operate as an independent or multi-zone universal smoke exhaust controller or in addressable detection lines/loops of the POLON 4000 system fire control panels as an addressable unit. Apart from 4 basic versions, there are over 30 additional ones available (in different configurations) from 4 A to 64 A, including high voltage equipment relays.

Supply voltage:- mains 230 V + 10% - 15%/50 Hz- reserve power supply: - cabinet up to 16 A batteries 2 x 12 V from 7.2 Ah to 9 Ah - cabinet from 32 A up to 64 A batteries 8 x 12 V from 7.2 Ah to 9 AhBattery current draw in quiescent mode < 120 mACurrent consumption from detection line of POLON 4000 system control panels < 0.6mAOperating voltage of control panel 24 V DC + 25% - 25%Operation temperature range from -10oC to +55oCIngress protection IP 30Dimensions - cabinet up to 16 A 400 x 400 x 160 mm- cabinet from 32 A up to 64 A 1150 x 630 x 190 mmMass (without batteries) - cabinet up to 1 < 8 kg- cabinet from 32 A up to 64 A < 40 kg

The PO-6x manual smoke exhaust buttons are designed for manual activa-tion of smoke flaps. Three kinds of the manual call points are available:• PO-61 manual button with a FIRE signal (flap activated),• PO-62 manual button with a FIRE signal and a stop/abort switch,• PO-63 manual button with a FIRE signal, OK (stand-by mode), FAULT signal and a stop/abort switch.The manual smoke exhaust buttons are designed for surface or semi-flush indoor mounting installation.

Max. connecting wire diameter 0.8 – 1.2 mmIngress protection IP 30Hole dimensions for semi-flush mounting ø 80 x 22 mmOperating temperature range from -25oC to +55oCDimensions 102 x 98 x 46 mmWeight < 220 gHousing colour orange

PP-61 and PP-62Daily ventilation switches are equipped with two buttons one for OPENING and one for CLOSING of fire window or fire damper. Switches are also equip-ped with electrical blockade which makes impossible use of two buttons at the same time.

Max wire section 1mm²Housing colour whiteIP rating IP 44Dimensions:PP-61 (surface mounted) 75 x 65 x 56 mmPP-62 (flush mounted) 80 x 80 x 40 mmMass 0.1 kg

SMOKE VENTILATION SYSTEM

Page 14: FIRE DETECTION - Polon-Alfa · system certificate in 1998. All devices manufactured by Polon-Alfa have been approved by the EU notified authorities with EC-Conformity Certificates

15

DESCRIPTION TECHNICAL DATAThe DOP-6001R beam smoke detector is designed for smoke detection at the start of a fire. It is especially suitable for protection of indoor spaces, in which the appearance of smoke is likely during ignition of a fire, and where, due to a large space area, installation of a greater number of point smoke detectors would be necessary. The DOP-6001R beam smoke detectors are equipped with fire alarm and fault relay outputs, which enable them to ope-rate in detection lines of any fire alarm system control panels as well as in burglar alarm systems.The DOP-6001R detector contains an infrared (IR) light transmitter and a re-ceiver located in a single housing and it uses an interoperating E39-R8 prism reflector or 4xE39-R8 reflector panel.

Operating voltage 9.5 ÷ 28 VQuiescent current (9.5 - 28 V) 8 ÷ 30 mAAlarm current (9.5 - 28 V) 20 ÷ 100 mAOperating distance with prism reflector 5 to 50 mOperating distance with reflector panel 50 to 100 mSensitivity thresholds (to be chosen) 18%, 30%, 50%Laser target viewfinder class 3RLaser viewfinder power supply 9 V 6F22 batteryRelay contact load (fault mode/fire alarm) 1 A/30 VDetectable test fires TF1 to TF5, TF7, TF8Operating temperature range from -25oC to +55oCDimensions 129 x 80 x 84 mm

The ADR-20N residential self-contained smoke detector and ADR-20R burglary system detector are designed to detect visible smoke at a start of a fire’s flameless stage when material starts to smoulder, a long time prior to the appearance of an open flame and a noticeable rise in temperature.They enables early detection of a fire in small residential facilities such as apartments, houses (in cellars, garages, attics, etc.). The ADR-20N detector is suitable for independent operation as well as operation in a network of several interconnected detectors, whereas the ADR-20R detector is equipped with a fire alarm relay and is intended to interoperate with detection lines of any burglar alarm system control panels.

Power supply: - ADR-20N 9 V 6F22 battery- ADR-20R 12 V (burglar alarm control panel)Min. operating voltage (ADR-20N) ≤7 VMonitoring current (ADR-20N) ≤ 10 µAAlarm relay (ADR-20R) switch-over contactRelay contact load capacity (ADR-20R) 1 A/30 V Audio alarm volume >85 dBColour whiteOperation temperature range from -10oC to +55oCRelative humidity up to 95% at 40oCDimensions of the detector (with base) ø112 x 57 mm

PPW-40REx detector provides high flame detection efficiency of fuels conta-ining hydrocarbons, while maintaining a high immunity to false alarms due a set of three infrared sensors operating in different bands.It is intended for use in potentially explosive mixtures of gases and vapors of flammable liquids with air (ATEX subgroups IIA, IIB, IIC) and in explosive air mixtures of combustible dust (ATEX subgroups IIIA, IIIB, IIIC). The detector is designed to be connected to such control panels that can receive an alarm signal from potential-free relay contacts, as well as cooperation with other systems using the 4 - 20 mA current loop. Detector is designed for indoor and outdoor application.

Power supply 24 V DC min. 18 V DC, max. 36 V DC

Max power consumption 9 W, 36 V DC (in an alarm mode

and with a heater ON)Fire detection sensitivity class

1 complies to PN-EN 54-10 standard

Direction angle horizontal 80 °Direction angle vertical 75 °Alarm relay output 5 A, 30 V DC, NO, NC contactsFault relay output 5 A, 30 V DC, NO contactsCurrent output 4 ÷ 20 mA

(max. loop resistance - 400 Ω)

Operation temperature range from -40°C to +75°CIP rating IP66Relative humidity up to 95% at 40°CMass 2.6 kg